• Electricity
    • Services
    • Safety around the network
    • Our Electricity Network
    • Disclosures
    • Electricity distribution pricing
    • Helpful advice
    • Electricity in New Zealand
    • Faults and outages
    • Consumerline
  • Fibre
    • About Us
    • Partners
    • Governance
    • Disclosures
    • Agreements
    • Faults and outages
    • Helpful Advice
    • Register Your Interest
  • Services
    • Distribution
    • Transmission
    • Fibre
    • Gas
  • Solutions
    • Foresight
  • Articles
    • Community
    • Fibre
    • Electricity
    • Solutions
    • Services
    • Company
    • Media
  • Company
    • About Us
    • Safety
    • Suppliers to Northpower
    • Careers at Northpower
    • Publications and Disclosures
    • Legal forms
  • Contact Us
    • Online Forms
    • General Enquiries
    • Faults & Outages
    • Locations
    • Complaints
    • Anonymous Whistle Blower
  • Home
  • Solutions
  • Foresight
  • Foresight in action

Examples of Foresight in action

Foresight has been deployed on over 200,000 poles, more than 20,000 sub-transmission poles and 2,500 transmission towers in Australia and New Zealand.

Foresight found over 2,000 electrical defects in these networks that were previously undetected through traditional inspection methods. 

Most of those 2,000+ defects had the potential to adversely impact network performance, reliability, security or safety.

Nrthpwr Foresight 0774

Accuracy

Not only is it more reliable, Foresight is also more accurate, finding the precise location of each problem. 

It runs at 10 times the speed of traditional methods, checking up to:

  • 300 distribution poles/structures per day
  • 30 - 50 transmission towers per day (depending on access)
  • 2 - 4 substations per day (depending on size and distance)

Foresight can detect potential problems at a very early stage, well before they actually become an issue, allowing companies to optimise their maintenance and replacement schedules.

Galvanic corrosion - resulting in micro-arcing and overheating

Galvanic corrosion occurs when two different metals make contact with one another (e.g. aluminium and copper) and the contact area is exposed to moisture. Micro-arcing causes pitting and erosion of the aluminium material and increases the contact resistance of the electrical connection.

Cable Termination Galvanic Corrosion

There's an increased risk of overheating of the connection/termination which may result in conductor burn, cracked insulators or cable compound leaks.

Advanced stages of this defect type are detectable with thermal imaging camera equipment and eventually through visual inspection. However, this is usually too late for minimising damage and supply disruption.

With Foresight, early detection is possible using acoustic inspection techniques, allowing you to implement a truly predictive-based maintenance model.

Surge Arrester Internal Damage 33K V

Defective surge arrester – resulting in hazardous leakage currents

Foresight has detected continuous discharge/leakage on surge arrester equipment, where the integrity of the surge arrester was most likely compromised due to lightning strikes. 

Internal damage has resulted in reduced energy capability and reduced rated voltage of surge arrester. This defect was not visible to the naked eye, and couldn't be detected using traditional inspection techniques.

A solid earth fault was a likely consequence which could have led to an increased risk to public safety (step and touch potential). Foresight's detection averted this.

Increased contact resistance – resulting in overheated cable termination

Foresight identified a cable termination defect, where incorrect installation (omission of a spring washer) had resulted in a high resistance termination and consequent overheating.

Thermal imaging can detect this defect type, but only when it's in advanced stages and when the conductor is under load.

Foresight detected this defect type at very early stages, prior to overheating occurring.

Cable Termination Increased Contact Resistance
Conductor Erosion

Intermittent binder contact – micro-arcing resulting in conductor erosion

Binder wire (tie wire) used to secure the conductor to the insulator must be in direct contact with the bare conductor to ensure electrical integrity.

Separation and/or any insulation between the conductor and binder wire can result in micro-arcing and conductor erosion. Electrical and mechanical properties of the conductor are ultimately compromised and can lead to unplanned outages (power supply interruption).

This defect type is extremely difficult to identify using visual inspection methods - even when in advanced stages of degradation.

Foresight's acoustic inspection can provide early detection of the micro-arcing generated by defects of this type, allowing for planned remedial action.

Reduced clearance distance – resulting in conductor erosion

Reduced clearance distance can result in leakage current between a conductor (jumper wire) and insulator. Continuous discharge (leakage current) can cause conductor erosion, conductor failure and unplanned network outages. This discharge can also contaminate and damage the insulator surface.

Leakage current from reduced clearance between conductors and insulators is easily detected using Foresight.

Jumper Touching Kidney Insulator
Glass Insulator Crack

Reduced leakage distance – cracked insulator causing flashover

A cracked insulator results in reduced leakage distance and can lead to electrical breakdown (flashover) and unplanned network outages.

Reduced leakage distance is able to be detected using Foresight.

Conductor clamp defects – resulting in conductor erosion

Foresight acoustic inspection is able to identify electrical discharge inside a conductor clamp – a defect which is impossible to detect using traditional inspection techniques. The discharge causes heavy pitting and erosion of the conductor (reduced cross-sectional area). The electrical and mechanical properties of the conductor are compromised and the defect can lead to conductor failure and unplanned outages. The discharge can also cause damage to the clamp.

Al Clamp
Hairline Crack On Glass Disc Insulator 220K V

Reduced leakage distance – cracked insulator causing flashover

A cracked insulator results in reduced leakage distance and can lead to electrical breakdown (flashover) and unplanned network outages.

Reduced leakage distance is able to be detected using Foresight acoustic inspection – in this case on a transmission tower from a distance of around 35m.

For more information

Find out how Foresight can assist you to identify network defects and improve maintenance planning and scheduling.

Contact Us
  • Electricity
  • Services
  • Safety around the network
  • Our Electricity Network
  • Disclosures
  • Electricity distribution pricing
  • Helpful advice
  • Electricity in New Zealand
  • Faults and outages
  • Consumerline
  • Fibre
  • About Us
  • Partners
  • Governance
  • Disclosures
  • Agreements
  • Faults and outages
  • Helpful Advice
  • Register Your Interest
  • Services
  • Distribution
  • Transmission
  • Fibre
  • Gas
  • Solutions
  • Foresight
  • Articles
  • Community
  • Fibre
  • Electricity
  • Solutions
  • Services
  • Company
  • Media
  • Company
  • About Us
  • Safety
  • Suppliers to Northpower
  • Careers at Northpower
  • Publications and Disclosures
  • Legal forms
  • Contact Us
  • Online Forms
  • General Enquiries
  • Faults & Outages
  • Locations
  • Complaints
  • Anonymous Whistle Blower
24 hour electricity faults & outages

Kaipara & Whangarei, call: 0800 10 40 40

© Northpower Limited 2019
Terms of Use Privacy Statement Remote Access

Need to report an electricity outage?

If you’re in the Kaipara & Whangarei areas, please get in touch

Call 0800 10 40 40
Loading outage information…
Need to report a fibre outage?

Please contact your retail service provider.

What can we help
you find?

  • Electricity
    Electricity
    • Services
    • Safety around the network
    • Our Electricity Network
    • Disclosures
    • Electricity distribution pricing
    • Helpful advice
    • Electricity in New Zealand
    • Faults and outages
    • Consumerline
  • Fibre
    Fibre
    • About Us
    • Partners
    • Governance
    • Disclosures
    • Agreements
    • Faults and outages
    • Helpful Advice
    • Register Your Interest
  • Services
    Services
    • Distribution
    • Transmission
    • Fibre
    • Gas
  • Solutions
    Solutions
    • Foresight
  • Articles
    Articles
    • Community
    • Fibre
    • Electricity
    • Solutions
    • Services
    • Company
    • Media
  • Company
    Company
    • About Us
    • Safety
    • Suppliers to Northpower
    • Careers at Northpower
    • Publications and Disclosures
    • Legal forms
  • Contact Us
    Contact Us
    • Online Forms
    • General Enquiries
    • Faults & Outages
    • Locations
    • Complaints
    • Anonymous Whistle Blower